Breast Pump Parts Explained: Valves, Membranes, Tubing and More
By Breastfeeding Mom Editorial TeamUpdated 5 min read

When a pump suddenly feels weaker, the motor usually isn’t the problem. More often, a small part has stretched, torn or been put together the wrong way. Knowing what each piece does makes it much easier to spot what needs replacing.
This guide walks through the parts of a typical pump kit, how each one wears, what “open” and “closed” system mean, and how to buy spares that fit. We don’t rank brands; we explain what to check. Find more in our pumping guides.
The basic parts of a breast pump
The FDA describes three main parts: the breast shield (flange), the pump that creates suction, and the milk container. On many pumps, plastic tubing connects the shield to the pump. Inside a typical kit you’ll find:
| Part | What it does | What it touches |
|---|---|---|
| Flange (breast shield) | Cone-shaped cup that fits over your nipple and areola | Your breast and milk |
| Connector | Joins the flange, valve, bottle and tubing | Milk |
| Valve (duckbill or valve with membrane) | Opens to let milk drop into the bottle, closes to keep suction | Milk |
| Backflow protector (on many pumps) | Barrier that keeps milk out of the tubing and motor | Sometimes milk |
| Tubing | Carries suction from the motor to the kit | Air only, when used correctly |
| Bottle or bag | Collects the milk | Milk |
| Motor unit | Creates and releases suction in cycles | Never milk |
The CDC lists flanges, valves, membranes, connectors and bottles as the parts that touch your breast or milk. Those need cleaning after every use.
How each part wears out
The Connecticut WIC program, in its guidance for families who exclusively pump, describes typical replacement triggers:
- Flanges usually only need replacing if your nipple size changes or the flange shows wear. If yours doesn’t fit well, our guide to flange inserts explains how to make a large flange smaller.
- Bottles should be replaced if they crack, grow mold, or connect loosely to the flange.
- Tubing should be replaced if moisture builds up, mold appears, it develops holes or tears, or it stretches and slips off the pump port.
- Valve membranes should be replaced if suction decreases or they show wear; WIC notes they may need replacing every 4 weeks for best performance.
- Backflow protectors can be replaced every 10 to 12 weeks, or sooner if suction drops or wear is visible.
Because WIC ties weaker suction to worn membranes and backflow protectors, inspect these soft parts closely when pumping feels different. Pump makers publish their own intervals, which depend on how often you pump. Our pump part replacement schedule turns those ranges into dates for your parts.
The motor wears too. The same WIC guidance says personal-use double electric pumps often aren’t designed for the heavy use of exclusive pumping, 8 to 12 times a day, notes that most motors have a 500-hour life span, and reminds families that their pump may have a one- or two-year warranty they can use if suction or function declines.
Open vs closed systems
You’ll often see pumps described as “open” or “closed” systems. These are terms used by pump makers and sellers; the FDA consumer pages we checked don’t define them. Makers generally use “closed” for a pump with a barrier, such as a backflow protector, between the milk and the tubing and motor, and “open” for one without.
What the FDA does say is clear. Multiple-user pumps are designed so that breast milk can never touch the working parts that are shared, and each user needs their own accessory kit (milk container, breast shield and tubing). Every other pump, including any personal pump labeled “closed”, is a single-user device in the FDA’s view, because there’s no way to guarantee it can be cleaned and disinfected between users. Never share or buy a used single-user pump.
If milk gets into the tubing
The CDC says to throw away tubing that has milk or mold in it, because it’s hard to clean properly, and to replace it with a new set. Then check why it happened: the valves or membranes may need replacing, or the tubing may have been attached incorrectly. The FDA says not to clean tubing unless milk gets into it, and to run the pump for a few minutes if condensation appears so the tubing dries. The CDC also suggests keeping a spare set of tubing on hand.
Troubleshooting weak suction
Before you replace anything, work through the simple checks:
- Reassemble the kit. The FDA says that if milk leaks out of your pump, stop and make sure it’s assembled correctly before trying again.
- Inspect the soft parts. Look for splits, stretched edges, or membranes that no longer lie flat.
- Check the tubing for water, milk, mold or a loose fit on the port.
- Swap in a spare valve or membrane if you have one, since WIC links drops in suction to worn membranes and backflow protectors.
- Call the maker if the problem continues. The FDA advises contacting the manufacturer’s customer service line if your pump keeps leaking or isn’t working as it should.
Buying replacement parts: what to check
- Your exact pump model. Parts that look similar may not seal on another pump. Use the maker’s parts list or a seller’s compatibility list for your model.
- Flange sizes. The FDA suggests checking the maker’s website to see whether you can replace the breast shields with a different size or texture that works with your pump.
- Valve style. Buy the type your pump uses, whether duckbill valves or valve-and-membrane sets.
- Cleaning method. Check whether parts are dishwasher-safe or can be boiled or steamed.
- Spares for busy days. A second set of the small soft parts lets you keep pumping while one set dries.
- Coverage. Some insurance plans cover pump parts; see our guide to getting a free breast pump through insurance for what to ask.
Cleaning parts so they last
The CDC’s routine is to take the kit apart after every use, rinse parts that touch milk under running water, wash them by hand in a separate basin or in a dishwasher, and air-dry them completely. It suggests sanitizing at least once a day, especially for babies under 2 months, born prematurely or with weakened immune systems. The FDA adds that the motor unit should only be wiped down and never put in water or a microwave sterilizer. Our step-by-step guide to cleaning breast pump parts covers every step.
When to call a lactation consultant or doctor
New parts and good cleaning fix most suction problems. See an IBCLC if pumping hurts, your nipples are damaged, or your milk output drops even with fresh parts, since flange fit or pump settings may be the issue. The FDA says to contact your health care provider if you’re injured while using a breast pump or have pain, and encourages reporting pump injuries or problems through its MedWatch program.
Shop on Amazon
Shop what this guide covers
Paid links: as an Amazon Associate we earn from qualifying purchases, at no extra cost to you. Links never change what we recommend. Disclosure
Frequently asked questions
Are duckbill valves and valve membranes interchangeable?
No, not unless your pump maker says so. Pumps are designed around one valve style, and many use either a duckbill valve or a valve-and-membrane set. Check the parts list in your manual.
If my pump is a closed system, can I share it or buy it used?
No. The FDA considers all breast pumps single-user devices except those designed for multiple users, because there's no way to guarantee they can be cleaned and disinfected between different users. That holds whatever the pump is marketed as.
Can I boil pump parts?
Only parts that are safe to boil. The CDC says to check the maker's instructions, then boil disassembled parts covered with water for 5 minutes and remove them with clean tongs. Never put the motor unit in water.
Do I need to wash the tubing every day?
No. The CDC says that when used correctly, tubing doesn't touch the milk and doesn't need routine cleaning. If you see water droplets, run the pump for a few minutes with the tubing attached until it dries.
Sources
- FDA: Types of Breast Pumpshttps://www.fda.gov/medical-devices/breast-pumps/types-breast-pumps
- FDA: What to Know When Buying or Using a Breast Pumphttps://www.fda.gov/consumers/consumer-updates/what-know-when-buying-or-using-breast-pump
- FDA: Cleaning a Breast Pumphttps://www.fda.gov/medical-devices/breast-pumps/cleaning-breast-pump
- FDA: Choosing a Breast Pumphttps://www.fda.gov/medical-devices/breast-pumps/choosing-breast-pump
- FDA: Buying and Renting a Breast Pumphttps://www.fda.gov/medical-devices/breast-pumps/buying-and-renting-breast-pump
- CDC: How to Clean and Sanitize Breast Pumpshttps://www.cdc.gov/hygiene/about/about-breast-pump-hygiene.html
- Connecticut WIC Program: Consistent Breastfeeding Education Messages: Exclusive Pumping (2022)https://portal.ct.gov/-/media/Departments-and-Agencies/DPH/dph/WIC-2018/Breastfeeding/Exclusive-Pumping-CT-WIC-June-2022-Final.pdf
This guide is general information, not medical advice. For your own situation, talk to your doctor, midwife, pharmacist or an IBCLC lactation consultant. Read our medical disclaimer and find breastfeeding support near you.
Related articles
How to Clean Breast Pump Parts: The CDC Steps, Simplified
How to clean breast pump parts the CDC way: washing after every use, sanitizing, air-drying, tubing and mold, the dishwasher and the fridge hack.
Wearable Breast Pump: How They Work, Pros and Cons, and Fit
An honest guide to wearable breast pumps: how they work, how they compare with traditional pumps, flange fit, cleaning and who they suit best.
How to Choose a Breast Pump: What to Look For
There's no single best breast pump. Choose by how you'll use it, using the FDA's questions on type, fit, cleaning, power, parts and returns.
Manual Breast Pump: Lever vs Silicone Pumps and How to Use One
How manual breast pumps work, lever vs silicone suction pumps, who they suit, how to use one step by step and how to keep the parts clean.



